Conclusions and Findings
Webster Environmental, Inc.
Confirmed that long detention times (periods of low flow) are causing in anaerobic conditions in the force main
Hydrogen sulfide is released to the atmosphere during initial aeration at the lagoons
Almost 90% of odor emissions are originating from Lagoon Cells 1/2 East and West
Routing all flows through new headworks will not result in considerable reduction of odors
Need to treat odors at the plant or prevent the formation of sulfides before the wastewater enters the lagoons